SCANTECH XT 30 X-Ray Thickness Gauge

SCANTECH XT 30 X-Ray Thickness Gauge
Tip
lot no. 806
Closing time: 17/12/2024 14:59
9,500 € Starting bid
Log in to bid
Use bidding agent
+ auction fee & VAT
SCANTECH XT 30 X-Ray Thickness Gauge
17/12/2024 14:59
Closing time
9,500 €
Starting bid
Name
SCANTECH XT 30 X-Ray Thickness Gauge
Item number
980017
Manufacturer
SCANTECH
Model / Type
XT 30
Documents
6U_Server_Rack_layout.pdf GENERAL_LAYOUT_ULO3-2500.pdf Bahnriss_Schluesselschalter.pdf CE_Declaration_of_conformity_de_STDE190001.pdf Flexscan_userguide_V2.2.1_de.pdf opc-ua_export_v1.0.pdf serverrack_datasheet.pdf ST00025-Installation_Guide_ULO3_rev_1.2_de.pdf ST00033-ULO3_Maintenance_Manual_rev_1.0_de.pdf ULO3_Electrical_drawing_A.9.pdf
Year of manufacture
2020
Item available from
immediately
Item condition
Location
Germany, 79379 Müllheim i.M.
Buyer’s premium
19 %
Dismantling & loading costs (binding)
500.00 €
Total Price
plus VAT
Shipping costs
not included
Delivery terms
FCA Müllheim i.M., loaded on truck
Payment terms
100% payment prior to collection
Approx. Onsite Dimension. (l x w x h)
unknown
  • Thickness gauge ULO3-2500, orientation Left-B
  • Flexscan 6 software
  • Operator interface
  • Server rack with replacement server and UPS
  • Communication interface OPC-UA
  • Supply voltage: 230V +/- 10%, 50Hz +/- 1%, 20 A, loadable neutral conductor
  • Electrical design: in accordance with VDE 100 with declaration of incorporation
  • Documentation: 2 x paper
  • Documentation language: 2 x German
  • Material: PVC foil
  • Thickness: 50µm to 1000µm
  • Web width: Max. 2100mm
  • Web speed: max. 200 m/min
  • Line type: PVC calender
  • Product tolerance: +/- 5% at 60µm, +/- 3µm
  • Measuring accuracy: +/- 0.3µm at 60µm
  • Temperatures:
    • Measuring point, sensor: < 45°C
    • Operating station: < 45°C
Parts list:

Scanner
  • Measuring frame ULO3 - 2500 mm
  • X-Ray sensor greater than 5keV acceleration voltage, max. 15keV
HMI
  • DELL PC (without mouse, screen and keyboard)
Server rack
  • 1 EATON UPS for bridging power failures
  • 2 server PCs to be able to continue using the other in the event of a failure
  • 1 switch
IO-BOX
  • 4x analog input (2x for your measurement position (4-20mA or 0-10V))
  • 4x Analog Output (statistical variables or mean values can be transmitted here via analog signal) (4-20mA or 0-10V)
  • 8x digital input (e.g. buttons that trigger actions on the scanner can be connected here. E.g. Start Scan, Stop Scan...)
  • 4x digital output (e.g. to control a lamp / horn if, for example, the average value is outside a tolerance)
Small parts
  • 1x rotary encoder (necessary for operation)
  • 3x draw-wire sensor for transferring the material width (optional)
  • 1x key/switch for bypassing a barrier sensor for maintenance purposes

The seller would like to expressly point out once again that the system must be commissioned with the manufacturer Scantech if it is not used as a spare parts store.
This should be clear to the buyer and, if necessary, clarified with Scantech in advance.
In addition, reference should be made to the approval of the system by the authorities / as well as the training of a radiation protection officer in accordance with specialist knowledge R3 (within Germany).
Automatic translation
Auction name
Wide Choice, Favourable Prices: Collective Auction Metalworking
lot no.
806
Documents
Spec. Auction Terms
Inspection
The exact location is available on request.
No fixed date. The items are in different locations (see item description). Viewing by appointment only!


Our services
  • Personal service in 16 languages
  • Consultation on site & from experts
  • Transportation organization on request
  • Support with papers & customs clearance